Park, C., Looney, D.
, Kidmose, P., Ungstrup, M. & Mandic, D. P. (2011).
Time-frequency analysis of EEG asymmetry using bivariate empirical mode decomposition.
I E E E Transactions on Neural Systems and Rehabilitation Engineering,
19(4), 366-373.
https://doi.org/10.1109/TNSRE.2011.2116805
Ahmed, M. U.
, Rehman, N., Looney, D., Rutkowski, T. M.
, Kidmose, P. & Mandic, D. P. (2012).
Multivariate entropy analysis with data-driven scales. I
2012 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP) (s. 3901-3904). IEEE.
https://doi.org/10.1109/icassp.2012.6288770,
https://doi.org/10.1109/ICASSP.2012.6288770
Wittenborn, T., Nielsen, T., Nygaard, J. V., Larsen, E. K. U.
, Thim, T., Rydtoft, L. M.
, Vorup-Jensen, T., Kjems, J., Nielsen, N. C., Horsman, M. R. & Falk, E. (2012).
Ultra-High-Field DCE-MRI of Angiogenesis in a Novel Angiogenesis Mouse Model.
Journal of Magnetic Resonance Imaging,
35(3), 703-710.
https://doi.org/10.1002/jmri.22855
Thrysøe, S. A., Nygaard, J. V., Niemann, A., Eldrup, N., Klærke, A., Paaske, W.
& Kim, W. Y. (2011).
Plaque geometry: determinant for fibrous cap stress levels.
Journal of Cardiovascular Magnetic Resonance,
13 (suppl 1), 376.
https://doi.org/10.1186/1532-429X-13-S1-P376
Thrysøe, S. A., Mikkelsen, A. F. S., Eldrup, N., Klærke, A., Paaske, W.
, Kim, W. Y. & Nygaard, J. V. (2012).
The Effect of Carotid Plaque Morphology on Longitudinal Fibrous Cap Stress Levels.
World Journal of Mechanics,
2, 216-223.
https://doi.org/10.4236/wjm.2012.24026
Nielsen, T., Bentzen, L., Pedersen, M. N.
, Tramm, T., Rijken, P. F. J. W., Bussink, J.
, Horsman, M. R. & Østergaard, L. (2012).
Combretastatin A-4 phosphate affects tumor vessel volume and size distribution as assessed using MRI-based vessel size imaging.
Clinical Cancer Research,
18(23), 6469-77.
https://doi.org/10.1158/1078-0432.CCR-12-2014
Looney, D.
, Kidmose, P., Park, C., Ungstrup, M., Rank, M. L., Rosenkranz, K. & Mandic, D. (2012).
The in-the-ear recording concept: User-centered and wearable brain monitoring.
I E E E Pulse,
3(6), 32-42.
https://doi.org/10.1109/MPUL.2012.2216717
Wagner, S. R., Rasmussen, N. H., Ahrendt, P., Toftegaard, T. S.
& Bertelsen, O. W. (2012).
Context classification during blood pressure self-measurement using the sensor seat and the audio classification device. I
The 6th International Conference on Pervasive Computing Technologies for Healthcare and Workshops (s. 201 - 202 ). ICST, The Institute for Computer Sciences, Social Informatics and Telecommunications Engineering.
http://ieeexplore.ieee.org/xpl/freeabs_all.jsp?arnumber=6240390
Laugesen, E., Høyem, P., Stausbøl-Grøn, B., Mikkelsen, A.
, Thrysøe, S., Erlandsen, M., Christiansen, J. S.
, Knudsen, S. T., Hansen, K. W., Kim, W. Y., Hansen, T. K. & Poulsen, P. L. (2013).
Carotid-Femoral Pulse Wave Velocity Is Associated With Cerebral White Matter Lesions in Type 2 Diabetes.
Diabetes Care,
36(3), 722-728.
https://doi.org/10.2337/dc12-0942
Kappel, S., Rathleff, M. S., Hermann, D., Simonsen, O.
, Karstoft, H. & Ahrendt, P. (2012).
A Novel Method for Measuring In-Shoe Navicular Drop during Gait.
Sensors,
12(9), 11697-711.
https://doi.org/10.3390/s120911697
Christensen-Dalsgaard, J., Brandt, C., Willis, K. L.
, Christensen, C. B., Ketten, D., Edds-Walton, P., Fay, R. R.
, Madsen, P. P. T. & Carr, C. E. (2012).
Specialization for underwater hearing by the tympanic middle ear of the turtle, Trachemys scripta elegans.
Proceedings of the Royal Society B: Biological Sciences,
279(1739).
https://doi.org/10.1098/rspb.2012.0290
Kusk, K., Nielsen, D. B., Thylstrup, T., Rasmussen, N. H., Jørvang, J.
, Pedersen, C. F. & Wagner, S. R. (2012).
Lessons Learned From a Lightweight Context-Aware System for Achieving Reliable Home Blood Pressure Self-Measurements. Afhandling præsenteret på NordiCHI 2012, The Nordic Conference on Human-Computer Interaction, Copenhagen, Danmark.
Fjord, S., Thrysøe, S., Robich, M. P., Paaske, W. P.
, Ringgaard, S., Bøtker, H. E., Hansen, E. S. S. & Kim, W. Y. (2012).
Assessment of intramyocardial hemorrhage by T1-weighted cardiovascular magnetic resonance in reperfused acute myocardial infarction.
Journal of Cardiovascular Magnetic Resonance,
14(59).
http://www.jcmr-online.com/content/14/1/59
Thim, T., Hagensen, M. K.
, Hørlyck, A., Kim, W. Y., Niemann, A. K.
, Thrysøe, S. A., Drouet, L., Paaske, W. P.
, Bøtker, H. E. & Falk, E. (2012).
Wall shear stress and local plaque development in stenosed carotid arteries of hypercholesterolemic minipigs.
Journal of Cardiovascular Disease Research,
3(2), 76-83.
https://doi.org/10.4103/0975-3583.95358
Larsen, E. K. U.
, Nielsen, T., Wittenborn, T., Rydtoft, L. M., Lokanathan, A. R., Hansen, L.
, Østergaard, L., Kingshott, P.
, Howard, K. A., Besenbacher, F., Nielsen, N. C. & Kjems, J. (2012).
Accumulation of magnetic iron oxide nanoparticles coated with variably sized polyethylene glycol in murine tumors.
Nanoscale,
4(7), 2352-2361 .
https://doi.org/10.1039/C2NR11554A
Niemann, A. K.
, Thrysoe, S., Nygaard, J. V., Hasenkam, M. & Petersen, S. E. (2012).
Computational Fluid Dynamics simulation of a-v fistulas: From MRI and ultrasound scans to numeric evaluation of hemodynamics.
Journal of Vascular Access,
13(1), 36-44.
https://doi.org/10.5301/JVA.2011.8440
Eriksen, H.-L. F., Gunnersen, K. F., Sørensen, J. A., Munk, T.
, Nielsen, T. & Knudsen, U. B. (2008).
Psychological aspects of endometriosis: differences between patients with or without pain on four psychological variables.
European Journal of Obstetrics & Gynecology and Reproductive Biology,
139(1), 100-5.
https://doi.org/10.1016/j.ejogrb.2007.10.002
Fjord Pedersen, S., Kim, W. Y., Paaske, W. P.
, Thim, T., Falk, E., Ringgaard, S. & Thrysøe, S. A. (2012).
Determination of acute vascular injury and edema in porcine carotid arteries by T2 weighted cardiovascular magnetic resonance.
International Journal of Cardiovascular Imaging,
28(7), 1717-1724.
https://doi.org/10.1007/s10554-011-9998-8
Bertelsen, L. B., Shen, Y. Y.
, Nielsen, T., Stødkilde-Jørgensen, H., Lloyd, G. K., Siemann, D. W.
& Horsman, M. R. (2011).
Vascular effects of plinabulin (NPI-2358) and the influence on tumour response when given alone or combined with radiation.
International Journal of Radiation Biology,
87(11), 1126-1134.
https://doi.org/10.3109/09553002.2011.605418
Fjord Pedersen, S., Thrysøe, S. A., Paaske, W. P.
, Thim, T., Falk, E., Ringgaard, S. & Kim, W. Y. (2011).
Determination of Edema in Porcine Coronary Arteries by T2 Weighted Cardiac Magnetic Resonance.
Journal of Cardiovascular Magnetic Resonance,
13(1), 52.
https://doi.org/10.1186/1532-429X-13-52
Kim, W. Y., Christiansen, E. H., Thrysøe, S. A., Al-Mashhadi, R. H., Bøtker, H. E., Bøttcher, M., Holm, N. R. & Falk, E. (2011).
First in vivo demonstration of coronary edema in culprit lesion of patient with acute coronary syndrome by cardiovascular magnetic resonance.
Circulation: Cardiovascular Imaging,
4, 344-6.
https://doi.org/10.1161/CIRCIMAGING.110.963074
Rubak, T.
, Thrysøe, S. A., Koefoed-Nielsen, B., Bonde, J. P.
& Kolstad, H. A. (2006).
The risk of noise-induced hearing loss in the Danish workforce.
Noise & Health,
8(31), 80-7.
Nielsen, S. L., Lomholt, M.
, Johansen, P., Hansen, S. B., Andersen, N. T. & Hasenkam, J. M. (2011).
Mitral ring annuloplasty relieves tension of the secondary but not primary chordae tendineae in the anterior mitral leaflet.
Journal of Thoracic and Cardiovascular Surgery,
141(3), 732-7.
https://doi.org/10.1016/j.jtcvs.2010.05.011
Shen, Y. Y., Liu, C.-X.
, Bertelsen, L. B., Nielsen, T., Horsman, M. R. & Stødkilde-Jørgensen, H. (2010).
NPI-2358 Rapidly Inhibit the Blood Flow in Tumour Treatment by Analyzing Dynamic Contrast Enhanced Magnetic Resonance Imaging Parameters.
China Journal of Cancer Prevention and Treatment,
7, 488-490.
Fjord, S., Thrysøe, S. A., Paaske, W. P.
, Thim, T., Falk, E., Ringgaard, S. & Kim, W. Y. (2011).
CMR Assessment of endothelial damage and angiogenesis in porcine coronary arteries using gadofosveset.
Journal of Cardiovascular Magnetic Resonance,
13, 10.
https://doi.org/10.1186/1532-429X-13-10
Stigö, A.
, Johansen, P., Jensen, M. Ø.
, Sivesgaard, K., Nygaard, H. & Sloth, E. (2010).
An automated in vitro model for the evaluation of ultrasound modalities measuring myocardial deformation.
Cardiovascular Ultrasound,
8, 40.
https://doi.org/10.1186/1476-7120-8-40
Nielsen, T., Bentzen, L. N., Pedersen, M., Horsman, M. R. & Østergaard, L. (2009).
Effect of Vascular Targeting on Tumor Vessel Volume and Size Distribution. Abstract fra ISMRM, Honolulu, Haiti.
Hokland, S., Nielsen, T., Moonen, C.
, Stødkilde-Jørgensen, H., Horsman, M. R. & Pedersen, M. (2009).
Assessing Thermal Damage Using Dynamic Contrast Enhanced MRI. Abstract fra ISMRM, Honolulu, Haiti.
Kallehauge, J. F., Tanderup, K., Haack, S., Nielsen, T., Muren, L. P., Fokdal, L.
, Lindegaard, J. C. & Pedersen, E. M. (2010).
Apparent Diffusion Coefficient (ADC) as a quantitative parameter in diffusion weighted MR imaging in gynecologic cancer: Dependence on b-values used.
Acta Oncologica,
49(7), 1017-22.
https://doi.org/10.3109/0284186X.2010.500305
Nielsen, T., Murata, R., Maxwell, R. J.
, Stødkilde-Jørgensen, H., Østergaard, L., Ley, C. D., Kristjansen, P. E. G.
& Horsman, M. R. (2010).
Non-invasive imaging of combretastatin activity in two tumor models: Association with invasive estimates.
Acta Oncologica,
49(7), 906-13.
https://doi.org/10.3109/0284186X.2010.499135
Niemann, A. K., Udesen, J.
, Thrysøe, S. A., Nygaard, J. V., Fründ, E.-T. W., Petersen, S. E.
& Hasenkam, J. M. (2010).
Can sites prone to flow induced vascular complications in a-v fistulas be assessed using computational fluid dynamics? Journal of Biomechanics,
43(10), 2002-9.
https://doi.org/10.1016/j.jbiomech.2010.02.037
Thrysøe, S. A., Oikawa, M., Yuan, C., Eldrup, N., Klaerke, A., Paaske, W. P.
, Falk, E., Kim, W. Y. & Nygaard, J. V. (2010).
Longitudinal distribution of mechanical stresses in carotid plaques of symptomatic patients.
Stroke,
41(5), 1041-3.
https://doi.org/10.1161/STROKEAHA.109.571588
Bertelsen, L. B., Shen, Y. Y.
, Nielsen, T., Lloyd, GK.
, Stødkilde-Jørgensen, H. & Horsman, M. R. (2009).
Vascular changes induced by the novel vascular disrupting drug NPI-2358 in a murine tumour model monitored with DCE-MRI. Abstract fra Dansk selskab for cancerforsknings årsmøde, Vilvorde, Danmark.
Bertelsen, L. B., Shen, Y. Y.
, Bohn, A. B., Nielsen, T., Loyd, GK.
, Stødkilde-Jørgensen, H., Siemann, DW.
& Horsman, M. R. (2010).
Time and dose dependent vascular effects of NPI-2358 in mouse tumour models. Poster session præsenteret på Time and dose dependent vascular effects of NPI-2358 in mouse tumour models.
Wittenborn, T., Nygaard, J. V., Horsman, M. R., Vorup-Jensen, T., Kjems, J., Thim, T., Nielsen, T., Larsen, E. K. U.
& Falk, E. (2009).
A Novel in Vivo Angiogenesis Mouse Model.
Arteriosclerosis, Thrombosis, and Vascular Biology, (7).